AP-02 audiometer
Laboratory of Medical Devices and Systems, Room 605, building 21

Purpose
Designed to determine human hearing thresholds by air conduction and for comparative assessment by bone conduction. Hearing thresholds are determined by presenting pure tones of different frequency and intensity to the subject. The results are recorded on an audiogram form from the patient's responses by marking points where the bars linked to the frequency and intensity switches cross.
Courses
Laboratory and practical work
- Audiometers and hearing aids. Design principles, structure and operating algorithms
Description and specifications
Specifications
- Hearing thresholds are determined by presenting pure tones of different frequency and intensity.
The results are recorded on an audiogram form from the patient's responses by marking points where the bars linked to the frequency and intensity switches cross.
- Pure tone frequencies: 125, 250, 500, 1000, 2000, 3000, 4000, 6000 and 8000 Hz +/- 4%
- Harmonic distortion of pure tones at the terminals of the air and bone conduction earphones at maximum intensity levels does not exceed: 7%
- Error of the maximum intensity level, no more than: +/- 3 dB
The intensity level is changed in steps of
- 6 +/- 1.5 dB
- The masking noise intensity level can be changed within: from 20 to 100 dB (in steps of 10 +/- 2 dB)
Other equipment in this laboratory
KL-720 medical measurement trainer
The KL-720 teaching and laboratory trainer is designed specifically for studying the electrical characteristics of sensors and transducers used to…
Samsung SBM-500S and SBM-600M blood pressure monitors
Automatic and semi-automatic blood pressure monitors for laboratory work in biophysics.
UZT.1.01F and UZT.1.07F ultrasound therapy devices
The UZT 1.01 F (EMA) ultrasound therapy device is designed for ultrasound treatment of various disorders of the peripheral nervous…
ETS-DMU-02 echotomoscope
The ETS-DMU-02 is a portable ultrasound device with angular mechanical scanning. It is designed to produce two-dimensional echograms of the…
MAG-30 magnetic therapy device
The device is designed to apply a therapeutic effect to the human body with an alternating non-uniform magnetic field. The…
EK1T-03M2 electrocardiograph
Designed to measure and graphically record the bioelectric potentials of the heart on heat-sensitive chart paper in medical institutions and…
Korona darsonval device
A compact device for local darsonvalisation. The compact Korona darsonval device replaces, complements and greatly enhances the effect of creams…
Tondi U-2M1 and Xingma XM-999e hearing aids
For mild and moderate hearing loss with a flat, gently sloping or gently rising pure-tone threshold audiogram